Show simple item record

dc.contributor.authorAfanador García, Nelson
dc.contributor.authorGuerrero Gómez, Gustavo
dc.contributor.authorNolasco Serna, Christian
dc.coverage.spatialColombiaen_US
dc.date.accessioned2025-10-15T15:15:11Z
dc.date.available2025-10-15T15:15:11Z
dc.date.issued2021
dc.identifier.issn1742-6596en_US
dc.identifier.urihttps://repositorioinstitucional.ufpso.edu.co/xmlui/handle/20.500.14167/5747
dc.description.abstractThe objective of this research work was to determine the resistance to cutting of clay block walls of size 1.20 m × 1.20 m without and with external reinforcement. Blocks of width equal to 0.10 m were used for four manufacturers, one located in Oca˜na, Colombia, and three more established in San Jos´e de C´ucuta, Colombia. Reinforcement with electrowelded mesh is an alternative to reduce the seismic vulnerability of homes in areas of intermediate and high seismic risk. Oca˜na, Colombia, is located in an intermediate seismic hazard zone and therefore the use of simple masonry in homes is not allowed. This made it necessary to determine the mechanical properties of the clay block pieces, such as compressive strength, compressive strength of the bonding mortar, compressive strength of clay block prisms, diagonal tensile strength, modulus of elasticity and shear modulus of reinforced and unreinforced walls. The tests were carried out on a universal machine with a compression capacity of 100 t, a tensile capacity of 60 t class B with a precision of 0.1% ± 0.05 mm. This research established the physical parameters of the clay block prisms and the physical behavior of shear deformation vs. Shear stress without and with exterior reinforcement, necessary to establish physical models of structural reinforcement of houses vulnerable to seismic movements, and with this avoid human losses.en_US
dc.language.isoengen_US
dc.relationhttps://iopscience.iop.org/article/10.1088/1742-6596/2046/1/012074/pdfen_US
dc.titleIn-plane behavior of clay blocks externally reinforceden_US
dc.title.translatedIn-plane behavior of clay blocks externally reinforceden_US
dc.contributor.cvlac[0000016699]en_US
dc.contributor.googlescholar[8Uk1lqUAAAAJ&hl]en_US
dc.contributor.googlescholar[La8nZsAAAAAJ&hl]en_US
dc.contributor.googlescholar[DriRZs4AAAAJ]en_US
dc.contributor.orcid[0000-0001-6923-3388]en_US
dc.contributor.researchgate[Christian-Serna]en_US
dc.contributor.scopus[57212415000]en_US
dc.description.abstractenglishThe objective of this research work was to determine the resistance to cutting of clay block walls of size 1.20 m × 1.20 m without and with external reinforcement. Blocks of width equal to 0.10 m were used for four manufacturers, one located in Oca˜na, Colombia, and three more established in San Jos´e de C´ucuta, Colombia. Reinforcement with electrowelded mesh is an alternative to reduce the seismic vulnerability of homes in areas of intermediate and high seismic risk. Oca˜na, Colombia, is located in an intermediate seismic hazard zone and therefore the use of simple masonry in homes is not allowed. This made it necessary to determine the mechanical properties of the clay block pieces, such as compressive strength, compressive strength of the bonding mortar, compressive strength of clay block prisms, diagonal tensile strength, modulus of elasticity and shear modulus of reinforced and unreinforced walls. The tests were carried out on a universal machine with a compression capacity of 100 t, a tensile capacity of 60 t class B with a precision of 0.1% ± 0.05 mm. This research established the physical parameters of the clay block prisms and the physical behavior of shear deformation vs. Shear stress without and with exterior reinforcement, necessary to establish physical models of structural reinforcement of houses vulnerable to seismic movements, and with this avoid human losses.en_US
dc.subject.proposalbehavior,reinforced,planeen_US
dc.subject.keywordsbehavior,reinforced,planeen_US
dc.publisher.facultyFacultad educación artes y humanidadesen_US
dc.type.redcolhttp://purl.org/redcol/resource_type/ARTen_US
dc.relation.referencesAdanur S 2010 Performance of masonry buildings during the 20 and 27 December 2007 Bala (Ankara) earthquakes in Turkey Natural Hazards and Earth System Sciences 10(12) 2547en_US
dc.relation.referencesPonce I, McNally K C, Gonzalez J, Del Castillo A, Gonzalez L, Chanel E, French M 1980 Oaxaca, Mexico, earthquake of 29 November 1978: a preliminary report on spatio-temporal pattern OE preceding seismic activity and mainshock relocation Geofisica Internacional 17(2) 109en_US
dc.relation.referencesMagenes G, Calvi G M 1998 In-plane seismic response of brick masonry walls Earthquake Eng. Struct. Dynamic 26(11) 109en_US
dc.relation.referencesPiscal-Ar´evalo C M, Afanador-Garc´ıa N, Medina S 2011 Resistencia a la comprensi´on de ladrillos en el municipio de Oca˜na Revista Ingenio 4(1) 12en_US
dc.relation.referencesAfanador N, Sanjuan Y, Medina D 2012 Dise˜no s´ısmico de muros de contenci´on en gravedad y voladizo Revista Colombiana de Tecnolog´ıas Avanzadas 2(20) 97en_US
dc.relation.referencesAfanador G N, Carrascal M, Bayona M J 2013 Experimentaci´on, comportamiento y modelaci´on de la tapia pisada Revista Facultad de Ingenier´ıa 22(35) 47en_US
dc.relation.referencesAfanador Garc´ıa N, Ib´a˜nez A C, L´opez C A 2013 Caracterizaci´on de arcillas empleadas en pasta cer´amica para la elaboraci´on de ladrillos en la zona de Oca˜na, Norte de Santander Revista Epsilon 20(1) 101en_US
dc.relation.referencesAfanador Garc´ıa N, Alvarez K F, Calder´on F 2019 A numerical model of the behavior of the resistance to ´ compression in prisms of solid masonry Journal of Physics: Conference Series 1386(1) 012131:1en_US
dc.relation.referencesBorri A, Castori G, Corradi M 2011 Shear behavior of masonry panels strengthened by high strength steel cords Construction and Building Materials 25(2) 494en_US
dc.relation.referencesIsmail N, Ptersen R B, Masia M J, Ingham J M 2011 Diagonal shear behaviour of unreinforced masonry wallettes strengthened using twisted steel bars Construction and Building Materials 25(12) 4386en_US
dc.relation.referencesChurilov S, Dumova-Jovanoska E 2012 Analysis of masonry walls strengthened with RC jackets In Proc. 15th World Conference on Earthquake Engineering (WCEE) (Lisbon: Curran Associates, Inc.) p 10en_US
dc.relation.referencesTanner J E, Klingner R E 2017 Masonry Structural Design (Bogot´a: McGraw-Hill Education)en_US
dc.relation.referencesInstituto Colombiano de Normas T´ecnicas y Certificaci´on (ICONTEC) 2005 M´etodos para Muestreo y Ensayos de Unidades de Mamposter´ıa y Otros Productos de Arcillas, NTC 4017 (Colombia: Instituto Colombiano de Normas T´ecnicas y Certificaci´on)en_US
dc.relation.references] American Society for Testing and Materials (ASTM) 2007 Standard Test Method for Diagonal Tension (Shear) in Masonry Assemblages, ASTM E519-07 (United States of America: American Society for Testing and Materials)en_US
dc.relation.referencesTimoshenko S 1983 History of Strength of Materials: With a Brief Account of the History of Theory of Elasticity and Theory of Structures (New York: Dover Publications)en_US
dc.identifier.DOI10.1088en_US


Files in this item

Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record