Show simple item record

dc.contributor.authorPérez Torrado, Wilson Antonio
dc.contributor.authorEspinel Blanco, Edwin
dc.contributor.authorVelásquez Pérez, Torcoroma
dc.coverage.spatialColombiaen_US
dc.date.accessioned2025-09-29T20:15:11Z
dc.date.available2025-09-29T20:15:11Z
dc.date.issued2022-03-16
dc.identifier.issn1742-6596en_US
dc.identifier.urihttps://repositorioinstitucional.ufpso.edu.co/xmlui/handle/20.500.14167/5630
dc.description.abstractEste artículo describe el diseño y la simulación de un controlador proporcional integral derivativo PID que acciona una válvula de control proporcional para permitir el flujo de agua caliente al suelo radiante de una granja porcina con el fin de mantener la temperatura requerida. En el desarrollo del proyecto se requieren conceptos físicos y matemáticos para controlar las oscilaciones de temperatura en el rango de 25 °C a 35 °C y el flujo de calor a través de la superficie radiante del suelo, así como analizar los parámetros involucrados para el desarrollo del sistema de control . En el diseño del sistema de control se identificaron las características y parámetros involucrados en la cría de cerdos mediante corral; posteriormente se realizó el análisis térmico del sistema de calefacción integrado en el suelo radiante que suministra calor para mantener la temperatura, luego se simuló la respuesta del sistema de control de temperatura en el software Scilab y finalmente se llevó a cabo la programación del control proporcional integrador. El diseño contempla el uso de gas generado en un biodigestor para transferir energía térmica al agua de calefacción que circula por el suelo, transfiriendo calor al módulo de cría hasta alcanzar y mantener la temperatura deseada mediante un sistema de control que implica un programa de válvula proporcional en Arduino. Todo el sistema se simuló mediante un software que incluía los circuitos de gas y agua, de acuerdo con el flujo de transferencia de calor necesario para mantener la temperatura controlada en el interior del módulo. El diseño desarrollado permite controlar el flujo de calor para mantener la temperatura requerida, estabilizando el proceso en 20 minutos.en_US
dc.language.isoengen_US
dc.relationhttps://iopscience.iop.org/article/10.1088/1742-6596/1938/1/012020/metaen_US
dc.titleDiseño de un controlador proporcional integral derivativo de temperatura regulada para una guardería.en_US
dc.title.translatedDesign of a proportional integral derivative controller of temperature regulated for a nurseryen_US
dc.contributor.cvlacWilson Antonio Pérez Torrado [0001775709]en_US
dc.contributor.cvlacEdwin Espinel Blanco [0001200917]en_US
dc.contributor.cvlacTorcoroma Velásquez Pérez [0000304891]en_US
dc.contributor.googlescholarEdwin Espinel Blanco [3ODKG4cAAAAJ]en_US
dc.contributor.googlescholarTorcoroma Velásquez Pérez [DTtZtu4AAAAJ]en_US
dc.contributor.orcidEdwin Espinel Blanco [0000-0003-4479-2874]en_US
dc.contributor.orcidTorcoroma Velásquez Pérez [0000-0002-2968-2338]en_US
dc.contributor.researchgateEdwin Espinel Blanco [57209774810]en_US
dc.contributor.researchgateTorcoroma Velásquez Pérez [Torcoroma-Perez]en_US
dc.contributor.scopusEdwin Espinel Blanco [57209774810]en_US
dc.contributor.scopusTorcoroma Velásquez Pérez [57205116150]en_US
dc.description.abstractenglishThis article describes the design and simulation of a proportional integral derivative PID controller that operates a proportional control valve to allow the flow of hot water to the radiant floor of a pig farm to maintain the required temperature. In the development of the project physical and mathematical concepts are required for controlling, the temperature oscillations in the range of 25 °C to 35 °C and the heat flux through the radiating surface of the floor, as well as analyzing the parameters involved for the development of the control system; In the control system design the characteristics and parameters involved in the pigs rearing by means of corral were identified; later the thermal analysis of the heating system integrated into the radiant floor that supplies heat to maintain the temperature was carried out, then the response of the temperature control system was simulated in the Scilab software and finally, the programming of the proportional integrative control was carried out. The design considers using gas generated in a biodigester to transfer thermal energy to the heating water that circulates through the floor, transferring heat to the brood module until it reaches and maintains the desired temperature using a control system that involves a proportional valve program in Arduino. The entire system was simulated by means of software including the gas and water circuits according to the heat transfer flow required to maintain the controlled temperature inside the module. The developed design allows controlling the heat flow to maintain the required temperature, stabilizing the process in 20 minutes.en_US
dc.subject.proposalDiseñoen_US
dc.subject.proposalcontrolador proporcionalen_US
dc.subject.proposaltemperatura reguladaen_US
dc.subject.proposalguarderíaen_US
dc.subject.keywordsDesignen_US
dc.subject.keywordsproportional controlleren_US
dc.subject.keywordstemperature regulateden_US
dc.subject.keywordsnurseryen_US
dc.publisher.facultyFacultad ingenieríasen_US
dc.type.redcolhttp://purl.org/redcol/resource_type/ARTen_US
dc.relation.referencesHongliu Y, Shaoran W, Gang D, Hongwei N, Xiaoping M, Guoguang D, Liu Y 2021 Research and Application of temperature indicating controller temperature probe replacement tool and test tool frame IOP Conf. Ser.: Earth and Environmental Sciences 687 012176:1en_US
dc.relation.referencesAmador G 2018 Control de Procesos Industriales con Minimización del Consumo Energético (Medellín: Universidad Nacional de Colombia)en_US
dc.relation.referencesHe Y, Li Y, Zheng K, Li G, Guo Z, Xu C 2020 Differential temperature controlin heat-integrated pressure-swing distillation for separating azeotropes to deal with operating pressure fluctuations Data in Brief 31 1en_US
dc.relation.referencesÁlvarez J G, Armero J M, Urrutia C A 2020 Control de temperatura en intercambiadores de calor tipo coraza-tubo: una revisión realizada en la industria Entre Ciencia e Ingeniería 14(27) 41en_US
dc.relation.referencesPaiano D, Moreira I, Quadros A, Milani N, Nunes M, Machado G, Da Silva A 2017 Efecto de la carga animal y el tipo de piso sobre el rendimiento, la temperatura de la piel y leucograma en la cria de cerdo Revista Medicina Veterinaria y Zootecnia 22(1) 5610en_US
dc.relation.referencesHörtenhuber S, Schauberger G, Mikovits C, Schönhart M, Baumgartner J, Niebuhr K, Piringer M, Anders I, Andre K, Hennig-Pauka I, Zollitsch W 2020 The effect of climate change-induced temperature increase on performance and environmental impact of intensive pig production systems Sustainability 12 9442en_US
dc.relation.referencesKhanA R, Elkamel A 2002 The Mathematical model for heat transfermechanism for particulate system Applied Mathematics and Computation 129 295en_US
dc.relation.referencesPiewthongngam K, Vijitnopparat P, Pathumnakul S, Chumpatong S, Duangjinda M 2014 System dynamics modelling of an integrated pig production supply chain Biosystems Engineering 127 24en_US
dc.relation.referencesWeixing Z, Chenyun D, Peng H 2012 Environmental control system based on IOT for nursery pig house transactions of the Chinese Society of Agricultural Engineering 28(11) 177en_US
dc.relation.referencesChing-Hung L, Ching-Cheng T 2000 Identification and control of dynamic systems using recurrent fuzzy neural networks IEEE Transactions on Fuzzy Systems 8(4) 349en_US
dc.relation.referencesBarros J, Rossi L, Menezes de Souza Z 2018 PID temperature controller in pig nursery: spatial characterization of thermal environment International Journal of Biometeorology 62 773en_US
dc.relation.referencesErdelyi V, Toth J, Janosi L, Farkas I 2020 Modelling experiments with small-scale thermal system used for pig fattener heating IOP Conf. Series: Materials Science and Engineering 749 012034:1en_US
dc.identifier.DOI10.1088/1742-6596/1938/1/012020en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record