| dc.contributor.author | Gallardo Amaya, Romel Jesús | |
| dc.contributor.author | Cely Calixto, Nelson Javier | |
| dc.contributor.author | Bonilla Granados, Carlos Alexis | |
| dc.coverage.spatial | Colombia | en_US |
| dc.date.accessioned | 2025-10-15T15:13:32Z | |
| dc.date.available | 2025-10-15T15:13:32Z | |
| dc.date.issued | 2021-10-01 | |
| dc.identifier.issn | 1742-6588 | en_US |
| dc.identifier.uri | https://repositorioinstitucional.ufpso.edu.co/xmlui/handle/20.500.14167/5746 | |
| dc.description.abstract | Estimar la cantidad de flujo que transporta el sistema de alcantarillado sanitario en una localidad es esencial para el diseño de nuevas instalaciones. Contar con un registro de los caudales permite el adecuado diseño hidráulico de un sistema de drenaje. El objetivo de este trabajo es determinar los parámetros físicos para la estimación del coeficiente de retorno que permite estimar los caudales para el alcantarillado sanitario de la cuenca hidrográfica de La Chivera, San José de Cúcuta, Colombia. En este sentido, se llevó a cabo un monitoreo en tiempo seco de las aguas residuales en el área de estudio. Los datos recolectados en el campo se utilizaron para construir la curva de variación de caudales por hora o hidrograma de entrada en el sistema de drenaje. Se estimaron los parámetros de caudal promedio por hora con un valor de 205,7 m3/h, valor registrado en la hora 11 del día. De igual manera, se determinó el caudal promedio diario con un valor de 180,3 m3/h, mientras que el factor de pico máximo fue de 1,14. Finalmente, a través de los parámetros físicos del alcantarillado sanitario, se determinó el coeficiente de retorno, el cual es de 0,72, valor que representa las condiciones del área de estudio. | en_US |
| dc.language.iso | en_US | en_US |
| dc.relation | https://iopscience.iop.org/article/10.1088/1742-6596/2073/1/012018/meta | en_US |
| dc.title | Parámetros físicos para la estimación del coeficiente de retorno en el alcantarillado de la cuenca hidrográfica de La Chivera | en_US |
| dc.title.translated | Physical parameters for the estimation of the return coefficient in the sewer of the La Chivera watershed | en_US |
| dc.contributor.cvlac | Romel Jesús Gallardo Amaya [0000883590] | en_US |
| dc.contributor.cvlac | Nelson Javier Cely Calixto [0001636110] | en_US |
| dc.contributor.cvlac | Carlos Alexis Bonilla Granados [0001638656] | en_US |
| dc.contributor.googlescholar | Romel Jesús Gallardo Amaya [kCbpxb4AAAAJ] | en_US |
| dc.contributor.googlescholar | Nelson Javier Cely Calixto [8ocDkoMAAAAJ] | en_US |
| dc.contributor.googlescholar | Carlos Alexis Bonilla Granados [If1ERuUAAAAJ] | en_US |
| dc.contributor.orcid | Romel Jesús Gallardo Amaya [0000-0002-4740-4841] | en_US |
| dc.contributor.orcid | Nelson Javier Cely Calixto [0000-0002-2083-6978] | en_US |
| dc.contributor.orcid | Carlos Alexis Bonilla Granados [0000-0002-4558-4615] | en_US |
| dc.contributor.researchgate | Nelson Javier Cely Calixto [N-Cely-Calixto] | en_US |
| dc.contributor.researchgate | Carlos Alexis Bonilla Granados [Carlos-Bonilla-11] | en_US |
| dc.contributor.scopus | Nelson Javier Cely Calixto [57220922255] | en_US |
| dc.contributor.scopus | Carlos Alexis Bonilla Granados [57527621100] | en_US |
| dc.description.abstractenglish | Estimating the amount of flow carried by the sanitary sewer system in a locality is essential for the design of new facilities. Having a record of the flow rates allows the adequate hydraulic design of a drainage system. The objective of this work is to determine the physical parameters for the estimation of the return coefficient that allows estimating the flow rates for the sanitary sewer of the La Chivera watershed, San José de Cúcuta, Colombia. In this sense, dry weather monitoring of the wastewater in the study area was carried out. The data collected in the field were used to construct the hourly flow variation curve or inflow hydrograph in the drainage system. The average hourly flow parameters were estimated with a value of 205.7 m3/h, a value recorded at the 11th hour of the day. Similarly, the average daily flow was determined with a value of 180.3 m3/h, while the maximum peak factor was 1.14. Finally, through the physical parameters of the sanitary sewer, the return coefficient was determined, which is 0.72, a value that represents the conditions of the study area. | en_US |
| dc.subject.proposal | Parámetros físicos | en_US |
| dc.subject.proposal | coeficiente de retorno | en_US |
| dc.subject.proposal | Alcantarillado | en_US |
| dc.subject.proposal | cuenca hidrográfica | en_US |
| dc.subject.keywords | Physical parameters | en_US |
| dc.subject.keywords | return coefficient | en_US |
| dc.subject.keywords | Sewerage | en_US |
| dc.subject.keywords | watershed | en_US |
| dc.publisher.faculty | Facultad ingenierías | en_US |
| dc.type.redcol | http://purl.org/redcol/resource_type/ARTDIV | en_US |
| dc.relation.references | Bonilla-Granados C, Becerra-Triviño J, Cifuentes-Ospina G 2019 A systematic review of wastewater monitoring and its applications in urban drainage systems Respuestas 24(3) 54 | en_US |
| dc.relation.references | Hrudka J, Csicsaiova R, Marko I, Stanko S, Skultetyova I 2020 The impact of intense rainfall on a storm sewage system of the east part of Trnava city IOP Conf. Ser.: Earth Environ. Sci. 444 012022 | en_US |
| dc.relation.references | Marko I, Csicsaiova R, Stanko S, Skultetyova I, Hrudka J 2020 Analysis of the recent state of sewage network in Serbia IOP Conf. Ser.: Earth Environ. Sci. 444 012038 | en_US |
| dc.relation.references | Ministerio de Vivienda, Ciudad y Territorio 2017 Reglamento Técnico para el Sector de Agua Potable y Saneamiento Básico – RAS, Resolución 0330 2017 (Colombia: Ministerio de Vivienda, Ciudad y Territorio) | en_US |
| dc.relation.references | Elvy M 2004 Development of Infiltration Factors for the Estimation of Urban Separate Wastewater Flow in the Gippsland Water Catchment (Toowoomba: University of Southern Queensland) | en_US |
| dc.relation.references | Hopcroft F 2014 Wastewater Treatment Concepts and Practices (New York: Momentum Press) | en_US |
| dc.relation.references | Empresas Publicas de Medellín (EPM) 2013 Normas de Diseño de Sistemas de Alcantarillado de E.P.M (Colombia: Empresas Públicas de Medellín) | en_US |
| dc.relation.references | Balacco G, Carbonara A, Gioia A, Iacobellis V, Ferruccio A 2017 Evaluation of peak water demand factors in puglia (Southern Italy) Water 9(2) 96 | en_US |
| dc.relation.references | Environmental Protection Agency (EPA) 1977 Process design manual: wastewater treatment facilities for sewered small communities, EPA-625/1-77-009 (United States of America: Environmental Protection Agency) | en_US |
| dc.relation.references | Sier D, Lansey K 2005 Monitoring sewage networks for sanitary sewer overflows Civ. Eng. Environ. Syst. 22(2) 123 | en_US |
| dc.relation.references | López-Cualla R 2003 Elementos de Diseño para Acueductos y Alcantarillados (Bogotá: Escuela Colombiana de Ingeniería) | en_US |
| dc.relation.references | Metcalf L, Eddy H, Tchobanoglous G 1991 Wastewater Engineering: Treatment, Disposal, and Reuse (New York: McGraw-Hill) | en_US |
| dc.relation.references | Scheaffer R, Mendenhall W, Ott R 1987 Elementos de Muestreo (México: Editorial Ibérica) | en_US |
| dc.identifier.DOI | 10.1088/1742-6596/2073/1/012018 | en_US |