Show simple item record

dc.contributor.authorAfanador García, Nelson
dc.contributor.authorGuerrero Gómez, Gustavo
dc.contributor.authorNolasco Serna, Christian
dc.coverage.spatialColombiaen_US
dc.date.accessioned2025-10-22T13:49:37Z
dc.date.available2025-10-22T13:49:37Z
dc.date.issued2022-09-24
dc.identifier.issn1742-6596en_US
dc.identifier.urihttps://repositorioinstitucional.ufpso.edu.co/xmlui/handle/20.500.14167/5859
dc.description.abstractLas construcciones de mampostería construidas con mortero y ladrillos sólidos de arcilla cocida están sujetas a: alto contenido de cemento, relación agua-cemento excesiva que causa problemas de retracción del mortero durante el curado y movimientos diferenciales entre el ladrillo y el mortero causados ​​por movimientos debidos al viento o eventos sísmicos. Los movimientos de tierra generan algunas fallas en muros de mampostería simple y mampostería confinada en juntas de ladrillos sólidos, principalmente con ángulos de inclinación de falla que varían de 45 a 50 grados. El objetivo de esta investigación fue estimar la resistencia a la flexión de la junta de mortero y el ladrillo sólido de arcilla cocida y, por lo tanto, establecer parámetros de diseño para mampostería no estructural en el municipio de Ocaña, Colombia. De los 18 fabricantes de ladrillos de arcilla cocida, se utilizó un muestreo aleatorio simple para determinar el tamaño de la muestra; se seleccionaron 4 fabricantes aleatoriamente. Además, se realizó la caracterización de las unidades de ladrillos macizos de arcilla cocida respecto a su resistencia a la compresión, tasa de absorción inicial y absorción final, así como del mortero respecto a su resistencia a la compresión a los 28 días, según la norma colombiana para construcciones sismorresistentes. Para la determinación de la resistencia a la flexión del mortero de unión y las unidades de ladrillo macizo, se diseñó una máquina semiautomática para ensayos de resistencia a la flexión de unidades de mampostería, Pinzuar modelo PC-13, con una medición de fuerza de 1000 N y una precisión de 0,1 N. La resistencia a la flexión en la junta de mampostería se obtuvo para el mortero tipo M con un valor de 0,26 MPa, con una desviación estándar de 0,01 MPa y un coeficiente de variación del 4,72 %. En cuanto a los morteros tipo N y S, la resistencia media fue de 0,24 MPa para ambos tipos, con una desviación estándar de 0,03 MPa y 0,01 MPa, respectivamente, y un coeficiente de variación del 11,4 % y el 3,18 % respectivamente. Dada la importancia de las variables, se realizó una interpretación de la relación física entre las propiedades: resistencia a la compresión del ladrillo macizo de arcilla cocida y resistencia a la flexión en la junta de mampostería, dado que sus valores medios fueron similares.en_US
dc.language.isoengen_US
dc.relationhttps://iopscience.iop.org/article/10.1088/1742-6596/2139/1/012017/metaen_US
dc.titleResistencia de la junta a flexión de juntas de mortero y prismas de ladrillos macizos de arcilla cocidaen_US
dc.title.translatedStrength of the flexural joint of mortar joints and solid fired clay brick prismsen_US
dc.contributor.cvlacNelson Afanador García [0000226920]en_US
dc.contributor.cvlacGustavo Guerrero Gómez [0001413037]en_US
dc.contributor.cvlacChristian Nolasco Serna [0000016699]en_US
dc.contributor.googlescholarNelson Afanador García [8Uk1lqUAAAAJ]en_US
dc.contributor.googlescholarGustavo Guerrero Gómez [La8nZsAAAAAJ]en_US
dc.contributor.googlescholarChristian Nolasco Serna [DriRZs4AAAAJ]en_US
dc.contributor.orcidNelson Afanador García [0000-0001-5463-2036]en_US
dc.contributor.orcidGustavo Guerrero Gómez [0000-0002-4316-7113]en_US
dc.contributor.orcidChristian Nolasco Serna [0000-0001-6923-3388]en_US
dc.contributor.researchgateNelson Afanador García [Nelson-Afanador]en_US
dc.contributor.researchgateChristian Nolasco Serna [Christian-Serna-2]en_US
dc.contributor.scopusNelson Afanador García [57202680756]en_US
dc.contributor.scopusGustavo Guerrero Gómez [57205119123]en_US
dc.contributor.scopusChristian Nolasco Serna [57212415000]en_US
dc.description.abstractenglishMasonry constructions built with mortar and solid fired clay bricks are subject to: high cement content, excessive water-cement ratio causing problems of mortar shrinkage during curing and differential movements between the brick and mortar caused by movements due to wind or seismic events. Earth movements generate some failures in simple masonry walls and confined masonry in solid brick joints, mainly with failure inclination angles varying from 45 degrees to 50 degrees. The objective of this research work was to estimate the flexural bond strength of the mortar joint and the solid fired clay brick and thus establish design parameters for non-structural masonry in the municipality of Oca˜na, Colombia. From the fired clay brick manufacturers, 18 in total, simple random sampling was used to determine the sample size, 4 manufacturers were randomly selected. In addition, the characterization of the solid fired clay brick units was carried out with respect to their compressive strength, initial absorption rate and final absorption, as well as the mortar with respect to its compressive strength at 28 days, according to the Colombian standard for earthquake resistant constructions; for the determination of the flexural strength of the bonding mortar and solid brick units, a semiautomatic machine for flexural strength testing of masonry units, Pinzuar model PC-13, with a force measurement of 1000 N and an accuracy of 0.1 N, was designed. The flexural strength at the masonry joint was obtained for mortar type M with a value of 0.26 MPa, with a standard deviation of 0.01 MPa and a coefficient of variation of 4.72%. As for mortars type N and S, the average strength value was equal to 0.24 MPa for the two types of mortar, with standard deviation of 0.03 MPa and 0.01 MPa respectively, and coefficient of variation of 11.4% and 3.18% respectively. Given the importance of the variables, an interpretation of physical of the relationship between the properties was made: compressive strength of the solid fired clay brick and flexural strength at the masonry joint, since their average values were similar.en_US
dc.subject.proposalResistenciaen_US
dc.subject.proposaljuntas de morteroen_US
dc.subject.proposalprismasen_US
dc.subject.proposalladrillos macizosen_US
dc.subject.keywordsStrengthen_US
dc.subject.keywordsmortar jointsen_US
dc.subject.keywordsprismsen_US
dc.subject.keywordssolid bricksen_US
dc.publisher.facultyFacultad ingenieríasen_US
dc.type.redcolhttp://purl.org/redcol/resource_type/ARTen_US
dc.relation.referencesGrenley D G 1969 Study of the effect of certain modified mortars on compressive and flexural strength of masonry Designing, Engineering, and Constructing with Masonry Products (Houston: Gulf Publishing Company)en_US
dc.relation.referencesHilsdorf H K 1969 An investigation into the failure mechanism of brick masonry loaded in axial compression Designing, Engineering, and Constructing with Masonry Products (Houston: Gulf Publishing Company)en_US
dc.relation.referencesKhoo C L, Hendry A W 1973 A failure criterion for brickwork in axial compression Proceedings of the 3rd Int. Brick Masonry Conference ed Foertig L Gobel K (London: MacMillan press) p 139en_US
dc.relation.referencesAtkinson R H, Noland J L, Abrams D P 1982 A deformation theory for stack bonded masonry prisms in compression Proceedings of the 7th Int. Brick Masonry Conference (Victoria: Melbourne University) p 565en_US
dc.relation.referencesMatthana M H 1996 Strength of Brick Masonry and Masonry with Openings (Bangalore: Indian Institute of Science)en_US
dc.relation.referencesSarangapani G 1998 Studies on the Strength of Brick Masonry (Bangalore: Indian Institute of Science)en_US
dc.relation.referencesAmerican Society for Testing and Materials (ASTM) 2013 Standard Test Methods for Measurement of Masonry Flexural Bond Strength, ASTM C1072-13 (United States of America: American Society for Testing and Materials).en_US
dc.relation.referencesInstituto Colombiano de Normas Técnicas y Certificación (ICONTEC) 2005 Métodos para Muestreo y Ensayos de Unidades de Mamposter´ıa y Otros Productos de Arcillas, Norma T´ecnica Colombiana, NTC 4017 (Colombia: Instituto Colombiano de Normas Técnicas y Certificación)en_US
dc.relation.referencesInstituto Colombiano de Normas Técnicas y Certificación (ICONTEC) 2004 Especificaciones del Mortero para Unidades de Mamposteria, Norma Técnica Colombiana, NTC 3329 (Colombia: Instituto Colombiano de Normas Técnicas y Certificación)en_US
dc.relation.referencesAsociacion Colombiana de Ingenieria Sismica 2010 Reglamento Colombiano de Construcion Sismo Resistente, NSR10 (Colombia: Asociacion colombiana de ingenieria sismica)en_US
dc.relation.referencesPiscal-Arévalo C M, Afanador-García N, Medina S 2011 Resistencia a la comprensión de ladrillos en el municipio de Ocaña Revista Ingenio 4 12en_US
dc.relation.referencesAfanador G N, Carrascal M, Bayona M J 2013 Experimentación, comportamiento y modelación de la tapia pisada Revista Facultad de Ingeniería 22(35) 47en_US
dc.relation.referencesAfanador García N, Ibáñez A C, López C A 2013 Caracterización de arcillas empleadas en pasta cer´amica para la elaboraciòn de ladrillos en la zona de Ocaña, Norte de Santander Revista Epsilon 20 101en_US
dc.relation.referencesAfanador Garc´ıa N, Alvarez K F, Calder´on F 2019 A numerical model of the behavior of the resistance to ´ compression in prisms of solid masonry Journal of Physics: Conference Series 1386(1) 012131:1-8en_US
dc.identifier.DOI10.1088/1742-6596/2139/1/012017en_US


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record