| dc.contributor.author | Afanador García, Nelson | |
| dc.contributor.author | Guerrero Gómez, Gustavo | |
| dc.contributor.author | Nolasco Serna, Christian | |
| dc.coverage.spatial | Colombia | en_US |
| dc.date.accessioned | 2025-10-22T13:14:53Z | |
| dc.date.available | 2025-10-22T13:14:53Z | |
| dc.date.issued | 2022-10-08 | |
| dc.identifier.issn | 1742-6596 | en_US |
| dc.identifier.uri | https://repositorioinstitucional.ufpso.edu.co/xmlui/handle/20.500.14167/5856 | |
| dc.description.abstract | En edificaciones, cada componente contribuye a la resistencia sísmica, y una parte importante de esta actividad son los muros de mampostería compuestos por ladrillo macizo de arcilla cocida de 120 mm de ancho y bloques de arcilla perforados horizontalmente de 100 mm y 150 mm de ancho. El objetivo principal de esta investigación es determinar la resistencia a la flexión de la junta de mortero de bloque de arcilla perforada horizontalmente, utilizando diferentes tipos de mortero, según lo establecido en el Reglamento Colombiano de Construcción Sismo Resistente, para cuatro proveedores del municipio de Ocaña, Colombia. Se diseñó una máquina semiautomática que considera las propiedades físicas de la aplicación de cargas para realizar el ensayo de flexión en juntas de mortero-bloque. Se determinó la resistencia a la flexión promedio en juntas de mortero-bloque para tres tipos de mortero, correspondientes a 0,219 MPa, 0,232 MPa y 0,291 MPa, respectivamente, para el municipio de Ocaña, Colombia. Esta investigación estableció una relación directa entre la resistencia a la compresión del mortero y la resistencia a la flexión de la junta de mortero de arcilla perforada horizontalmente de 100 mm de ancho. Se realizó una comparación física de la resistencia a la compresión del prisma y la resistencia a la flexión de la junta de mortero de arcilla con la obtenida por otros investigadores en la India, obteniendo resultados bastante similares. | en_US |
| dc.language.iso | eng | en_US |
| dc.relation | https://iopscience.iop.org/article/10.1088/1742-6596/2163/1/012006/meta | en_US |
| dc.title | Resistencia física de la junta a flexión en juntas de mortero y prismas de bloques de arcilla | en_US |
| dc.title.translated | Physical resistance of the flexural joint in mortar Joints and clay blocks prisms | en_US |
| dc.contributor.cvlac | Nelson Afanador García [0000226920] | en_US |
| dc.contributor.cvlac | Gustavo Guerrero Gómez [0001413037] | en_US |
| dc.contributor.cvlac | Christian Nolasco Serna [0000016699] | en_US |
| dc.contributor.googlescholar | Nelson Afanador García [8Uk1lqUAAAAJ] | en_US |
| dc.contributor.googlescholar | Gustavo Guerrero Gómez [La8nZsAAAAAJ] | en_US |
| dc.contributor.googlescholar | Christian Nolasco Serna [DriRZs4AAAAJ] | en_US |
| dc.contributor.orcid | Nelson Afanador García [0000-0001-5463-2036] | en_US |
| dc.contributor.orcid | Gustavo Guerrero Gómez [0000-0002-4316-7113] | en_US |
| dc.contributor.orcid | Christian Nolasco Serna [0000-0001-6923-3388] | en_US |
| dc.contributor.researchgate | Nelson Afanador García [Nelson-Afanador] | en_US |
| dc.contributor.researchgate | Christian Nolasco Serna [Christian-Serna-2] | en_US |
| dc.contributor.scopus | Nelson Afanador García [57202680756] | en_US |
| dc.contributor.scopus | Gustavo Guerrero Gómez [57205119123] | en_US |
| dc.contributor.scopus | Christian Nolasco Serna [57212415000] | en_US |
| dc.description.abstractenglish | In buildings, each component contributes to resisting seismic forces and an
important part in this activity are the masonry walls composed of: fired clay solid brick of 120
mm width and horizontally perforated clay blocks of 100 mm and 150 mm width. The main focus
of this research is to determine the flexural strength of the horizontally perforated clay blockmortar joint, using different types of mortar as established in the “Reglamento Colombiano de
Construcion Sismo Resistente” for four suppliers used in the municipality of Oca˜na, Colombia.
A semi-automatic machine that takes into account the physics in the application of loads was
designed to carry out the flexural test in mortar-block joints. The average flexural strength
in mortar-block joints was determined for three types of mortar corresponding to 0.219 MPa,
0.232 MPa, and 0.291 MPa respectively, for the municipality of Oca˜na, Colombia. This research
established a direct relationship between the compressive strength of the mortar and the flexural
strength of the 100 mm wide horizontally perforated clay mortar-block joint. A physical
comparison was made in terms of the compressive strength of the prism and the flexural strength
of the clay mortar-block joint with that obtained by other researchers in India and found quite
similar results. | en_US |
| dc.subject.proposal | Resistencia física | en_US |
| dc.subject.proposal | juntas de mortero | en_US |
| dc.subject.proposal | bloques de arcilla | en_US |
| dc.subject.keywords | Physical strength | en_US |
| dc.subject.keywords | mortar joints | en_US |
| dc.subject.keywords | clay blocks | en_US |
| dc.publisher.faculty | Facultad ingenierías | en_US |
| dc.type.redcol | http://purl.org/redcol/resource_type/ART | en_US |
| dc.relation.references | Venumadhava R K, Venkatarama R B V, Jagadish K S 1995 Influence of flexural bond strength on the compressive strength of masonry Proc. Nat. Conf. on Civil Eng. Materials and Structures (Osmania: University of Hyderabad) p 103 | en_US |
| dc.relation.references | Hilsdorf H K 1969 An investigation into the failure mechanism of brick masonry loaded in axial compression Designing, Engineering, and Constructing with Masonry Products (Houston: Gulf Publishing) p 34 | en_US |
| dc.relation.references | Atkinson R H, Noland J L, Abrams D P 1982 A deformation theory for stack bonded masonry prisms in compression Proceedings of the 7th Int. Brick Masonry Conference (Victoria: Melbourne University) | en_US |
| dc.relation.references | Matthana M H 1996 Strength of Brick Masonry and Masonry with Openings (Bangalore: Indian Institute of Science) | en_US |
| dc.relation.references | Sarangapani G 1998 Studies on the Strength of Brick Masonry (Bangalore: Indian Institute of Science) | en_US |
| dc.relation.references | Instituto Colombiano de Normas T´ecnicas y Certificaci´on (ICONTEC) 1994 M´etodo de Ensayo para Determinar por Secado el Contenido Total de Humedad de los Agregados, Norma T´ecnica Colombiana, NTC 1776 (Colombia: Instituto Colombiano de Normas T´ecnicas y Certificaci´on) | en_US |
| dc.relation.references | García N A, Gómez G G, Sepúlveda R M 2012 Propiedades físicas y mecánicas de ladrillos macizos cerámicos para mampostería Ciencia e Ingeniería Neogranadina 22 43 | en_US |
| dc.relation.references | Instituto Colombiano de Normas Técnicas y Certificación (ICONTEC) 2000 Especificaciones de los Agregados para Concreto, Norma Técnica Colombiana, NTC 174 (Colombia: Instituto Colombiano de Normas Técnicas y Certificación) | en_US |
| dc.relation.references | Instituto Colombiano de Normas Técnicas y Certificación (ICONTEC) 1994 Método de Ensayo para Determinar por Secado el Contenido Total de Humedad de los Agregados, Norma Técnica Colombiana, NTC 1776 (Colombia: Instituto Colombiano de Normas Técnicas y Certificación) | en_US |
| dc.relation.references | Instituto Colombiano de Normas Técnicas y Certificación (ICONTEC) 1995 Método para Determinar la Densidad y la Absorción del Agregado Fino, Norma Técnica Colombiana, NTC 237 (Colombia: Instituto Colombiano de Normas Técnicas y Certificación) | en_US |
| dc.relation.references | Instituto Colombiano de Normas Técnicas y Certificación (ICONTEC) 1999 Cementos Método de Ensayo para Determinar la Densidad del Cemento Hidráulico, Norma Técnica Colombiana, NTC 221 (Colombia: Instituto Colombiano de Normas Técnicas y Certificación) | en_US |
| dc.relation.references | Asociacion Colombiana de Ingenieria Sismica (NSR) 2010 Reglamento Colombiano de Construcion Sismo Resistente, NSR-10 (Colombia: Asociacion Colombiana de Ingenieria Sismica) | en_US |
| dc.relation.references | American Society for Testing and Materials (ASTM) 1999 Standard Test Methods for Measurement of Masonry Flexural Bond Strength, ASTM-1072 (United States of America: American Society for Testing and Materials) | en_US |
| dc.relation.references | Sarangapani G, Venkatarama Reddy B V, Jagadish K S 2005 Brick-mortar bond and masonry compressive strength Journal of Materials in Civil Engineering 17(22) 229 | en_US |
| dc.relation.references | Piscal-Arévalo C M, Afanador-García N, Medina S 2011 Resistencia a la comprensión de ladrillos en el municipio de Ocaña Revista Ingenio 4 12 | en_US |
| dc.relation.references | Afanador García N, Alvarez K F, Calderón F 2019 A numerical model of the behavior of the resistance to ´ compression in prisms of solid masonry Journal of Physics: Conference Series 1386(1) 012131:1 | en_US |
| dc.relation.references | Garcia N A, Carrascal M, Bayona M J 2013 Experimentación, comportamiento y modelación de la tapia pisada Revista Facultad de Ingeniería 22(35) 47 | en_US |
| dc.relation.references | Afanador G N, Prada Y S, Cáceres 2013 Diseño sismico de muros de contención en gravedad y voladizo Revista Colombiana de Tecnologias de Avanazada 2(20) 97 | en_US |
| dc.identifier.DOI | 10.1088/1742-6596/2163/1/012006 | en_US |