| dc.contributor.author | Moreno Pacheco, Luis Alfonso | |
| dc.contributor.author | Sánchez Hueto, Leopoldo José Luis | |
| dc.contributor.author | Barbosa Saldaña, Juan Gabriel | |
| dc.contributor.author | Martínez Trinidad, José | |
| dc.contributor.author | Toledo Velázquez, Miguel | |
| dc.contributor.author | García León, Ricardo Andrés | |
| dc.coverage.spatial | Colombia | en_US |
| dc.date.accessioned | 2025-10-10T13:26:46Z | |
| dc.date.available | 2025-10-10T13:26:46Z | |
| dc.date.issued | 2024-11-26 | |
| dc.identifier.issn | 2411-9660 | en_US |
| dc.identifier.uri | https://repositorioinstitucional.ufpso.edu.co/xmlui/handle/20.500.14167/5713 | |
| dc.description.abstract | Esta investigación se centra en el análisis de las características aerodinámicas de las corrientes de aire residuales generadas por el movimiento de vehículos y en la evaluación de su viabilidad para la generación de energía, para posteriormente diseñar un aerogenerador de eje vertical. Los parámetros evaluados incluyen el perfil característico de velocidad, las velocidades media y máxima, la duración de las perturbaciones, así como la frecuencia y probabilidad de recurrencia de estas perturbaciones. Con los datos, se realizan proyecciones sobre la cantidad de energía eléctrica que puede producir un aerogenerador operando en dichas condiciones de viento. Se tomaron mediciones en cuatro ubicaciones: tres dentro de la Ciudad de México (CDMX) y una en las afueras. La estación de medición, que consiste en una torre vertical de 2.35 m equipada con ocho anemómetros termorresistivos alineados verticalmente, está instalada en medianas a menos de 0.50 m de los vehículos en movimiento. Los datos de la CDMX muestran velocidades máximas del viento que oscilan entre 6 y 8 m/s a nivel del suelo, mientras que las mediciones en las afueras registran velocidades de hasta 19.5 m/s. Un análisis probabilístico revela que las corrientes de aire aprovechables podrían estar presentes el 58 % del tiempo. Según cálculos de producción eléctrica, se estima que el aprovechamiento de esta energía residual podría abastecer a aproximadamente 4500 hogares, considerando el costo nacional por kWh y el consumo eléctrico promedio de un hogar de cuatro personas. | en_US |
| dc.language.iso | eng | en_US |
| dc.relation | https://www.mdpi.com/2411-9660/8/6/126 | en_US |
| dc.title | Evaluación del potencial de energía eólica generada por vehículos: un estudio de caso en México | en_US |
| dc.title.translated | Assessment of the potential for wind energy generated by vehicles: a case study in Mexico | en_US |
| dc.contributor.cvlac | Ricardo Andrés García León [0001454975] | en_US |
| dc.contributor.googlescholar | Luis Alfonso Moreno Pacheco [YlG3DnQAAAAJ] | en_US |
| dc.contributor.googlescholar | Juan Gabriel Barbosa Saldaña [LLYVUyQAAAAJ] | en_US |
| dc.contributor.googlescholar | José Martínez Trinidad [l2OsFsQAAAAJ] | en_US |
| dc.contributor.googlescholar | Ricardo Andrés García León [emeJT3sAAAAJ] | en_US |
| dc.contributor.orcid | Luis Alfonso Moreno Pacheco [0000-0001-8723-8836] | en_US |
| dc.contributor.orcid | Juan Gabriel Barbosa Saldaña [0000-0001-8590-8082] | en_US |
| dc.contributor.orcid | José Martínez Trinidad [0000-0002-5445-2681] | en_US |
| dc.contributor.orcid | Miguel Toledo Velázquez [0000-0002-0342-3848] | en_US |
| dc.contributor.orcid | Ricardo Andrés García León [0000-0002-2734-1425] | en_US |
| dc.contributor.researchgate | Ricardo Andrés García León [Ricardo-Garcia-Leon] | |
| dc.contributor.scopus | Luis Alfonso Moreno Pacheco [23976809300] | en_US |
| dc.contributor.scopus | Juan Gabriel Barbosa Saldaña [22950055000] | en_US |
| dc.contributor.scopus | José Martínez Trinidad [8432492800] | en_US |
| dc.contributor.scopus | Miguel Toledo Velázquez [6507836226] | en_US |
| dc.contributor.scopus | Ricardo Andrés García León [57192545232] | en_US |
| dc.description.abstractenglish | This research focuses on analyzing the aerodynamic characteristics of residual air currents
generated by vehicle movement and evaluating their feasibility for energy generation, then designing
a vertical axis wind turbine. The parameters assessed include the characteristic velocity profile, the
average and maximum velocities, disturbance lifetimes, as well as the frequency and probability of
recurrence of these disturbances. Using the data, projections are made on the electrical energy amount
that can be produced by a wind turbine operating under such wind conditions. Measurements were
taken at four locations: three within Mexico City (CDMX) and one on the outskirts. The measurement
station, consisting of a 2.35 m vertical tower equipped with eight vertically aligned thermos-resistive
anemometers, is installed on medians less than 0.50 m from moving vehicles. The data from within
CDMX show maximum wind velocities ranging from 6 to 8 m/s at ground level, while measurements
on the outskirts record velocities of up to 19.5 m/s. A probabilistic analysis reveals that usable air
currents could be present 58% of the time. Based on electrical production calculations, it is estimated
that harnessing this residual energy could power approximately 4500 homes, considering the national
cost per kWh and the average electricity consumption of a four-person household. | en_US |
| dc.subject.proposal | Anemometría | en_US |
| dc.subject.proposal | Energía renovable | en_US |
| dc.subject.proposal | Energía residual | en_US |
| dc.subject.proposal | Sostenibilidad | en_US |
| dc.subject.proposal | Energía eólica | en_US |
| dc.subject.proposal | Potencial eólico | en_US |
| dc.subject.keywords | Anemometry | en_US |
| dc.subject.keywords | Renewable energy | en_US |
| dc.subject.keywords | Residual energy | en_US |
| dc.subject.keywords | Sustainability | en_US |
| dc.subject.keywords | Wind energy | en_US |
| dc.subject.keywords | Wind potential | en_US |
| dc.publisher.faculty | Facultad ingenierías | en_US |
| dc.type.redcol | http://purl.org/redcol/resource_type/ART | en_US |
| dc.relation.references | Petersen, E.L. In search of the wind energy potential. J. Renew. Sustain. Energy 2017, 9, 52301. [CrossRef] | en_US |
| dc.relation.references | Lonca, G.; Muggéo, R.; Imbeault-Tétreault, H.; Bernard, S.; Margni, M. Does material circularity rhyme with environmental efficiency? Case studies on used tires. J. Clean. Prod. 2018, 183, 424–435. [CrossRef] | en_US |
| dc.relation.references | Kalthoff, N.; Bäumer, D.; Corsmeier, U.; Kohler, M.; Vogel, B. Vehicle-induced turbulence near a motorway. Atmos. Environ. 2005, 39, 5737–5749. [CrossRef] | en_US |
| dc.relation.references | Saqr, K.M.; Musa, M.N. A perspective of the Malaysian highway energy consumption and future power supply. Energy Policy 2011, 39, 3873–3877. [CrossRef] | en_US |
| dc.relation.references | Kumar, M.; Kumar, K.; Rana, R.Wind energy generation from traffic movement. DU J. Undergrad. Res. Innov. 2016, 2, 116–120. | en_US |
| dc.relation.references | Kumar, M.; Kumar, K. Traffic-Driven energy generator. Technol. Lett. 2016, 3, 10–13. | en_US |
| dc.relation.references | Sayais, S.Y.; Salunkhe, G.P.; Patil, P.G.; Khatik, M.F. Power generation on highways by using vertical axis wind turbine & solar system. Int. Res. J. Eng. Technol. 2018, 5, 2133–2137. | en_US |
| dc.relation.references | Kumar-Rathore, M.; Agrawal, M.; Baredar, P. Energy production potencial from wake of moving traffic vehicles on a highway by the array of low economic VAWT. Mater. Today Proc. 2021, 46, 5272–5277. [CrossRef] | en_US |
| dc.relation.references | Santhakumar, S.; Palanivel, I.; Venkatasubramanian, K. A study on the rotational behaviour of a Savonius wind turbine in low rise highways during different monsoons. Energy Sustain. Dev. 2017, 40, 1–10. [CrossRef] | en_US |
| dc.relation.references | Tian, W.; Mao, Z.; An, X.; Zhang, B.; Wen, H. Numerical study of energy recovery from wakes of moving vehicles on highways by using a vertical axis wind turbine. Energy 2017, 141, 715–728. [CrossRef] | en_US |
| dc.relation.references | Kurz, D.; Bugala, A.; Gluchy, D.; Kasprzyk, L.; Szymenderski, J.; Tomczewski, A.; Trzmiel, G. The use of renewable energy sources in road construction and public transport: A review. Energies 2024, 17, 2141. [CrossRef] | en_US |
| dc.relation.references | Tian,W.; Song, B.; Mao, Z. Numerical investigation of wind turbines and turbine arrays on highways. Renew. Energy 2020, 147, 384–398. [CrossRef] | en_US |
| dc.relation.references | ˙Ilkiliç, C. Wind energy and assessment of wind energy potential in Turkey. Renew. Sustain. Energy Rev. 2012, 16, 1165–1173. [CrossRef] | en_US |
| dc.relation.references | Keyhani, A.; Ghasemi-Varnamkhasti, M.; Khanali, M.; Abbaszadeh, R. An assessment of wind energy potential as a power generation source in the capital of Iran, Tehran. Energy 2010, 35, 188–201. [CrossRef] | en_US |
| dc.relation.references | Wu, J.;Wang, J.; Chi, D.Wind energy potential assessment for the site of Inner Mongolia in China. Renew. Sustain. Energy Rev. 2013, 21, 215–228. [CrossRef] | en_US |
| dc.relation.references | Alayat, M.M.; Kassem, Y.; Çamur, H. Assessment of Wind Energy Potential as a Power Generation Source: A Case Study of Eight Selected Locations in Northern Cyprus. Energies 2018, 11, 2697. [CrossRef] | en_US |
| dc.relation.references | Morbiato, T.; Borri, C.; Vitaliani, R. Wind energy harvesting rom transport systems: A resource estimation assesment. Appl. Energy 2014, 133, 152–168. [CrossRef] | en_US |
| dc.relation.references | García-León, R.A.; Gomez-Camperos, J.; Jaramillo, H. Bibliometric analysis in brake disc: An overview. Dyna 2021, 88, 23–31. [CrossRef] | en_US |
| dc.relation.references | Sivaranjani, S.; Velmurugan, S.; Kathiresan, K.; Karthik, M.; Gunapriya, B.; Gokul, C.; Suresh, M. Visualization of virtual environment through labVIEW platform. Mater. Today Proc. 2021, 45, 2306–2312. [CrossRef] | en_US |
| dc.relation.references | Martínez Bencardino, C. Estadística Y Muestreo; ECOE: Bogotá, Colombia, 2012. | en_US |
| dc.relation.references | Predictiva. Cálculo de los Parámetros de la Distribución de Weibul. WebPage. 2019. Available online: https://predictiva21.com/ parametros-distribucion-weibull/ (accessed on 9 September 2024). | en_US |
| dc.relation.references | Gimenez Alvarez, J.M.; Gomez Targarona, J.C. Wind Generation Using Different Generatos Considering Their Impact on Power Systems. Dyna 2011, 78, 95–104. Available online: https://revistas.unal.edu.co/index.php/dyna/article/view/20070 (accessed on 12 May 2024). | en_US |
| dc.relation.references | Hemami, A. Wind Turbine Technology; Illustrate; Cengage Learning: Boston, MA, USA, 2012. | en_US |
| dc.relation.references | Kamoji, M.A.; Kedare, S.B.; Prabhu, S.V. Performance tests on helical Savonius rotors. Renew. Energy 2009, 34, 521–529. [CrossRef] | en_US |
| dc.relation.references | Uribe, I.M. Valuation of the wind as a source of wind energy in the state of Guerrero. Ing.-Rev. 2018, 22. Available online: http://www.nco.ncep.noaa.gov/pmb/products/ (accessed on 16 June 2024). | en_US |
| dc.relation.references | Samal, R.K. Assessment of wind energy potential using reanalysis data: A comparison with mast measurements. J. Clean. Prod. 2021, 313, 127933. [CrossRef] | en_US |
| dc.relation.references | Rahman, S.M.; Chattopadhyay, H. Statistical assessment of wind energy potential for power generation at Imphal, Manipur (India). Energy Sources Part A Recovery Util. Environ. Eff. 2023, 45, 7376–7388. [CrossRef] | en_US |
| dc.relation.references | Serrano Rico, J.C. Comparación de métodos para determinar los parámetros de Weibull para la generación de energía eólica. Sci. Tech. 2013, 18, 315–320. Available online: https://www.redalyc.org/articulo.oa?id=84929153004 (accessed on 13 June 2024). | en_US |
| dc.relation.references | Sánchez Hueto, L.J.L. Diseño de un Generador Eólico Accionado por Corrientes Residuales Producidas por Automóviles; Instituto Politecnico Nacional: Mexico City, Mexico, 2020. | en_US |
| dc.relation.references | Saad, M. Comparison of Horizontal Axis Wind Turbines and Vertical Axis Wind Turbines. IOSR J. Eng. 2014, 4, 27–30. [CrossRef] | en_US |
| dc.relation.references | Tong,W. Wind Power Generation and Wind Turbine Design; WIT Press: Billerica, MA, USA, 2010. | en_US |
| dc.identifier.DOI | https://doi.org/10.3390/designs8060126 | en_US |